Specification Range 11th Edition The UK's Leading Ventilation Company www.vent-axia.com

A warm welcome to the latest edition of the Vent-Axia Specification Range catalogue. As part of the ongoing drive for energy efficiency within Europe, ventilation devices over 30 Watts come under the scope of the Energy Related Products Directive that came into force on 1st January 2016. The legislation sets minimum performance criteria across a range of fans and ventilation devices under two sets of legislation;'residential' ventilation and'non-residential' ventilation. As a result of the legislation we have reviewed our products and where required made updates to ensure they comply. In line with Vent-Axia's drive to provide the best solution for our customer, we have taken the opportunity to update and improve some products at the same time as bringing the products in-line with ErP regulations. We have also improved the way we supply some of them-giving you more choice and flexibility over how you stock and sell the products. This edition of our Specification Range catalogue show s the continued investment we are making in our products and services to improve and add to our already comprehensive range. In this catalogue, we have bought together our Lo-Carbon residential and our non-residential products in one place providing what we believe to be the best solutions for a wide range of specification today. We have introduced many new models which expand upon our traditional, well-proven products as well as broadening our capabilities further with a whole host of innovations in Vent-Axia Lo-Carbon and energy reducing ventilation solutions. For example, the EKF kitchen fan has a built in EC motor speed control, high temperature rating of up to 120 degrees, motor out of the airstream and specific fan powers of below 1 W/l/s; we believe there is no better solution available. We thank you for your continued custom and feedback, and are always willing to answer any questions you may have. If you need to contact us, please email sales@vent-axia.com, or speak to your l ocal representative who will be happy to help. Kind Regards Mark Hoskins Managing Director Why choose Vent-Axia Vent-Axia supplies heat recovery solutions to countries around the world, whose building regulations already demand the most effective, sustainable and energy efficient ventilation solutions. We are with you all the way • Unparalleled customer service • Industry leading design support • Providing support and solutions on-site Availability • With the widest distribution network of any manufacturer in the UK we pride ourselves on having products available when and where you need them Product solutions • Whatever the product category, we have the most energy efficient solutions available • Unique solutions designed to fit into all your buildings • With absolute focus on the end user we work hard to produce the quietest, most comfortable products for occupiers to live with Unparalleled Customer Service On-site Support Industry Leading Design Support Widest UK Distribution Network Ventilation Solutions 

Legislation Approved Document F 2010-Means of Ventilation The purpose of this regulation is to ensure adequate means of ventilation is provided for people in the building. According to the document, ventilation is the'removal of stale air from a building and replacement with fresh outside air.' By providing fresh outside air to breath, ventilation assists in the dilution and removal of pollutants as well as a reduction in humidity/condensation, which combined create a more pleasant environment and relief for asthma and allergy sufferers. Part F is a performance based whole building solution stating not only what should be achieved, but also guidance on how this can be achieved. The pollutants in today's modern dwellings has lead to these changes, with the types of pollutant and the acceptable levels now detailed in the Approved Document Part F 2010. Nitrogen Dioxide (NO 2) Carbon Monoxide (CO 2) Total volatile compounds (TVOC) Bio-effluents (body odours) Within ADF 2010, Ventilat ion requirements for new build properties reference the whole dwelling based on an analysis of floor area, number of bedrooms and occupants. There are four systems covered in ADF 2010 including Intermittent Extract Fans, Passive Stack, Continuous Mechanical Extract Ventilation (MEV) and Mechanical Ventilation with Heat Recovery (MVHR). A guide called the'Domestic Ventilation Compliance Guide' is available. This covers installation practices as well as sign off and commissioning. Efficiency regulations require buildings to be better sealed and more airtight. In ADF 2010 there are two ventilation rates based on the deign infiltration rate of your building. There is one rate for properties with infiltration rates over 5m 3 h/m 2 (leakier properties) and a higher ventilation rate for properties below 5m 3 h/m 2 (tighter properties) . The practical outcome of this means that in airtight properties, the following applies: • Trickle vents with intermittent fans are up to 50% bigger • MVHR rates are increased With MEV in properties at 5m 3 h/m 2 or over no trickle vents are needed. Guidance is available for ventilation of basements in houses and trickle ventilation for replacement windows. Compliance with Part F requires installed performance to meet the ventilation rates quoted in the Document. This means that ventilation has to be commissioned and signed off by a competent person. Noise With increasing airtightness the acoustic properties also improve leading to a reduction in external noise entering our dwellings. However this makes any noise generated inside the property even more noticeable, so in Part F a maximum noise level of 35dB(A) has been set for the trickle speed on continuous ventilation systems. Approved Document L 2013 – Conservation of Fuel and Power These documents set minimum performance levels for ventilation efficiencies and reducing the consumption of the systems. These regulations have brought some significant changes to the ventilation sector in a bid to improve both air quality and energy efficiency. Part L – Overview • Target emission rates, along with fabric energy efficiency standards are aimed at reducing the carbon emissions by 6% • Non-domestic building services compliance guide shows specific fan power requirements. Heat recovery efficiency minimums to EN308 test standard • Specific fan power (SFP) targets of 1 W/l/s for new or replacement commercial kitchen extract systems • Minimum energy efficiency level for all ventilation systems. New build and refurbishment applications for intermittent fans must have an SFP of less than 0.5 W/l/s. 

4 As part of the ongoing drive for energy efficiency within Europe, as of January 2016 ventilation devices over 30 Watts now come under the scope of the Energy Related Products Directive. The legislation sets minimum performance criteria across a range of fans and ventilation devices under two sets of legislation;'residential' ventilation and'non-residential' ventilation. As a result of the legislation we have reviewed our products and where required made updates to ensure they comply. The primary changes have meant that a number of products have had alternative motors specified or have been updated to enable speed control. However, we have ensured that the installation methods remain unaffected. Through the review we have also taken the opportunity to rationalise our range where needed. All relevant products in this literature have been updated as required by the ErP legislation. Please note that where a product changes due to ErP, there will be a transitional period as we move fro m the old to the new model, and any stock you currently hold will not be affected by this regulation and can be sold as normal. Residential Products Residential Products has a secondary directive which requires some products to carry an energy label as described below: Residential Ranges – Small fans The majority of small residential fans are unaffected by the legislation as any device below 30 Watts is currently out of scope. The information on them is recorded however and can be found at www.vent-axia.com/erp The Duet and Gemini fans have been delisted, but are still available as spares so please contact sales@vent-axia for more information. MVHR and MEV products These products do come into the scope of the legislation and will carry an energy label. There are some minimum energy efficiency requirements as well as the requirement for a summer bypass on heat recovery models. A small number of our products have been updated to ensure they meet these requirements. The following produ ct has been discontinued: • Kinetic E Energy Efficiency Class Products within the scope of ErP now need to carry a rating that shows their Energy Efficiency Class. This information is called a'SEC Class' and is provided in all product literature and on the energy label. A product's SEC class is affected by how the product is controlled. This is referred to as Local Demand Control (LDC) and indicates how many'sensors' a fan should have. The regulations require that single room fans, such as a bathroom fan, should have at least 1 sensor. Units that are ducted, such as an MEV unit, need to have more than one sensor. Examples of these are a pull cord/light switch or humidistat. In our literature, where appropriate we have shown the rating if an additional LDC was added to a product. In those cases, you will see a table similar to the one below which has a heading (incl LDC). This is so you can choose the most efficient option for your needs. SEC Rating Example Model SEC Class SEC Class ( inc. LDC) HR200 CB 1 1 Manufacturers name 1 2 Model name 1 3 Energy Efficiency Class 1 4 Max flow rate 1 5 Sound Level 2016 1254/2014 dB ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE m 3 /h C Vent -Axia 443028L 66 252 1 3 1 1 1 4 1 5 1 2 Energy Related Products Directive (ErP)

5 Non-Residential Ranges Non-Residential products have had minimum performance and efficiency levels established, but there is no requirement to introduce energy labels. Some products have been updated with new motors and enabled for speed control. Non-Residential ranges are split into a number of different categories dependent on their application and function. These can be described as follows: 1. Fans 2. Uni-directional Ventilation Units 3. Bi-directional Ventilation Units 1. Fans These are products where there is a simple single case that directs air on and off the impellor. Examples include axial plate and case fans. These examples are out of scope of the legislation. Changes to the way we sell products The ErP regulations gave us the opportunity to review our product ranges and in some cases has enabled us to improve the way we stock and sell them. Examples of this include T-Series and Standard Range fans. You can now buy these as either the entire product or in modular format. The entire product can be purchased using the existing part number that you have always used. Alternatively, you can purchase just the motor core or just the fitting kit as required. If you are unsure of the new part number don't worry, as we will be able to tell you what the new one is. In some instances however you may receive more than one box. 

6 2. Unidirectional ventilation units This includes products that are one direction only, and where there is a secondary housing around a fan. This is the product category which has required the most changes. The impact of the efficiency legislation has meant that it has become virtually impossible to comply using a forward curved AC centrifugal fan. We have therefore moved to backward curved centrifugal fans in all of our AC box fan ranges. This has meant changes to the box sizes and adjustment to performances across the range. The product ranges have therefore been updated: ACQ/ATQ QP/QPTW We have a number of product ranges that have been reaching the end of their life cycle and we have taken the opportunity to rationalise these and where possible provide a suitable alternative range. The following product ranges are no longer available: VMD RMV GRB GDB GRD Other product ranges have been rationalised to provide one solution, these include: ARH – rationalised to MFQ RBH – rational ised to RMH 3. Bi-directional ventilation unitsThese are product ranges that both supply and extract such as heat recovery. There are now minimum energy requirements set for heat recovery efficiency. Any product with an efficiency of 67% or lower does not comply. Both the Totus 2 and ERV-HIBOX ranges are unaffected by these changes, however the low efficiency heat recovery ERV-BOX products have been discontinued. Heat recovery minimum efficiency 67% 67% Energy Related Products Directive (ErP)

7 Things have moved on a bit since 1992 when ventilation was first introduced into the Building Regulations. Here is an overview of the changes from 2006. 2006 – Part F included continuous ventilation for the first time. Ventilation systems were being installed by skilled persons but the performance data was never tested. Part L changes meant that SAP Q products could be included as part of the dwelling's SAP calculations. 2010 – Design, install and ensure its used correctly. With dwellings being designed with increased energy efficiency and reduced air permeability, ventilation systems now require specific flow rates and there is more demand for highly efficient heat recovery to help reduce the DER's. Ventilation is now required to be installed correctly with the installation recorded and measured plus there needs to be guidance to the home occupier as to how it operates. 2013 – New Part L requirements meant a reduction in air leakage and increased air tightness. These trends continu e to drive the adoption of higher efficiencies and the importance of installation increases as the advantageous air from leakage is reducing further. 2016 – With the commitments made in the recent COP21 meeting and the Paris climate agreement, focus on decarbonisation and energy efficiency is set to continue. The Energy Performance of Buildings directive and the Energy related Product Directive are having an impact on the performance and efficiency standards of ventilation. These drivers will continue to develop and are expected to transform into standards in the future meaning an even greater focus on energy efficiency. The commitment to zero carbon buildings in 2019 will mean revisions to Part F and L of the building regulations are likely. As we focus our efforts to drive down the energy that we use in buildings, the risk of airtight, well insulated buildings being the potential cause of respiratory problems increase. Therefore the importance of well-designed and well installed sys tems that perform as designed increases. This will lead to increased focus on competence when installing ventilation and is likely to drive advances in the way installers are trained. Things to Remember • Airflow performance • Minimum energy efficiency limits • Good installation • Use by occupiers Future Direction 

8 LO-CARBON RESIDENTIAL FANS 12-35 Lo-Carbon Svara- Up to 30l/s Lo-Carbon iQ- Up to 37l/s Continuous Running Lo-CarbonVA100 ® /SELV-Up to 21l/s Lo-CarbonSilhouette ® 100/SELV -Up to 30l/s Lo-Carbon Centra ® /SELV-Up to 15l/s Continuous Running NEW Lo-Carbon Revive/SELV-Up to 60l/s Lo-Carbon Solo ® Plus/SELV- Up to 21l/s Continuous Running Page 14-15 Page 16-17 Page 18-19 Page 20-21 Page 22-23 Page 24-25 Page 26-27 Lo-Carbon Minivent- Up to 31l/s Lo-Carbon LEDVent-A-light- Up to 31l /s Lo-Carbon Quadra ® /SELV-Up to 63l/s Continuous Running Lo-Carbon Silhouette 125- Up to 44l/s Lo-Carbon VA150- Up to 64l/s Lo-Carbon Silhouette ® 150-Up to 65l/s Page 28 Page 29 Page 30-31 Page 32 Page 33 Page 34-35 dMEV, MEV & PIV SYSTEMS 36-55 Lo-Carbon Centra ® /SELV-Up to 15l/s (54m 3 /h) Continuous Running Lo-Carbon Response -Up to 13l/s (47m 3 /h) Continuous Running Lo-Carbon Multivent- Up to 120l/s (432m 3 /h) Multivent- Up to 123l/s (443m 3 /h) Lo-Carbon Sentinel ® Mult ivent/Plus-Up to 165l/s (595m 3 /h) Lo-Carbon Multivent MVDC-MS/MSH- Up to 121l/s (436m 3 /h) Page 38-39 Page 40-41 Page 42-43 Page 44 -45 Page 46-49 Page 50-51 Lo-Carbon PoziDry- Up to 50l/s (180m 3 /h) Lo-Carbon PoziDry Compact- Up to 34l/s (122m 3 /h) Page 52-53 Page 54- 55 SINGLE ROOM dMVHR 56-63 Lo-CarbonTempra/SELV- Up to 15l/s (54m 3 /h) Continuous Running HR200WK- Up to 61l/s (220m 3 /h) HR300- Up to 83l/s (299m 3 / h) Page 58-59 Page 60-61 Page 62-63 Contents

9 MVHR UNITS FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 64-115 Lo-Carbon Sentinel Kinetic ® Advance- Up to 115l/s (414m 3 /h) Page 66-67 Lo-Carbon Sentinel Kinetic ®-Up to 76l/s (274m 3 / h) Page 72-75 Lo-Carbon Sentinel Kinetic ® FH-Up to 93l/s (335m 3 /h) Page 76-79 Lo-Carbon Sentinel Kinetic ® Plus-Up to 136l/s (490m 3 /h) Page 80 -83 Lo-Carbon Sentinel Kinetic ® High Flow-Up to 195l/s (702m 3 /h) Page 84-85 Lo-Carbon Sentinel Kinetic ® Cooker Hood-Up to 76l/s (274m 3 /h) Page 86-89 Lo-Carbon Sentinel Kinetic ® Horizontal- Up to 98l/s (353m 3 /h) Page 90-95 Lo-CarbonKinetic ® Plus E-Up to 141l/s (508m 3 /h) Page 96-99 Integra ®-Up to 48l/s (173m 3 /h) Page 100-101 NEW Integra ® Plus EC-Up to 130l/s (54m 3 /h) Page 102-103 HR100R/RS- Up to 18l/s (65m 3 /h) Page 104-105 HR200V- Up to 103l/s (371m 3 /h) Page 106-107 HR500- Up to 250l/s (900m 3 /h) Page 108-109 HR500D- Up to 174l/s (626m 3 /h) Page 110-111 HR500EP/IP- Up to 244l/s (878m 3 /h) Page 112-113 HR500DP- Up t o 333l/s (1,199m 3 /h) Page 114-115 DUCTING & FITTINGS 116-141 HEATING RANGE 142-161 Bluethermal ® Underfloor Heating- Up to 3,300W Page 144-149 Heated Towel Rails- Up to 400W Page 150-151 Radiant Heaters- Up to 6,000W Page 152-153 Opal ® Aluminium Radiators-Up to 1,500W Page 154 Optimax ® Plus Panel Heaters- Up to 2,000W Page 155 Optimax ® Plus Combination Storage Heaters- Up to 3,400W Page 156 Optimax ® Plus Storage Heaters- Up to 3,400W Page 157 Plinth Heaters- Up to 2,000W Page 158 Warm Air Curtains- Up to 6,000W Page 159 Convector Heater- Up to 2,000W Page 160 Portable Fan Heater- Up to 2,000W Page 161

10 Contents COMMERCIAL RANGE 162-205 ACM ® 100-200-Up to 240l/s (864m 3 /h) Page 164-165 ACM ® 250-315-Up to 653l/s (2,351m 3 /h) Page 166-167 Powerflow- Up to 340l/s (1,220m 3 /h) Page 168-169 Lo-Carbon T-Series ® Window Model- Up to 430l/s (1,550m 3 /h) Page 172-173 Lo-Carbon T-Series ® Wall Model- Up to 460l/s (1,650m 3 /h) Page 174-175 Lo-Carbon T-Series ® Roof Model- Up to 330l/s (1,194m 3 /h) Page 176-177 Lo-Carbon T -Series ® Panel Model- Up to 490l/s (1,761m 3 /h) Page 178-179 Traditional T-Series ® Window Model- Up to 449l/s (1,615m 3 /h) Page 182-183 Traditional T-Series ® Wall Model- Up to 485l/s (1,745m 3 /h) Page 184-185 Traditional T-Series ® Roof Model- Up to 412l/s (1,485m 3 /h) Page 186-187 Traditional T-Series ® Panel Model- Up to 524l/s (1,885m 3 /h) Page 188-189 Traditional T-Series ® Darkroom Model- Up to 314l/s (1,130m 3 /h) Page 190-191 Traditional T-Series ® Inline Model- Up to 620l/s (2,230m 3 /h) Page 192-193 Super T-Series- Up to 1372l /s (4,940m 3 /h) Page 194-195 Traditional StandardWindow Model- Up to 433l/s (1,560m 3 /h) Page 198-199 Traditional StandardRoof Model- Up to 314l/s (1,130m 3 /h) Page 200-201 Traditional StandardWall Model- Up to 491l/s (1,767m 3 /h) Page 202-203 Traditional StandardPanel Model- Up to 531l/s (1,910m 3 /h) Page 204-205 ACCESSORIES & CONTROLLERS-RESIDENTIAL & LIGHT COMMERCIAL SYSTEMS 206-225 PLATE & CASE FAN RANGE 226-301 Sabre Plate Mounted Sickle Fans (VSP)- Up to 5.71m 3 /s (20,556m 3 /hr) Page 228-233 Sabre Sickle Short Case Fans (VSC)- Up to 5.81m 3 /s (20,916m 3 /hr) Page 234-241 Long Case Axial Fans (LCA)- Up to 36.01m 3 /s (129,600m 3 /hr) Page 242-271 Kitchen Axial Fans (KAF)- Up to 5.93m 3 /s (21,348m 3 /hr) Page 272-275 Bifurcated Case Axial Fans (BIFA)- Up to 19.10m 3 /s (68,760m 3 /hr) Page 276-301

11 IN-LINE FAN RANGE 302-341 Lo-Carbon Kitchen Box Fan (EKF)- Up to 3.69m 3 /s (13,284m 3 /hr) Page 304-311 NEW Acoustic In-Line Fans (ACQ)- Up to 1.5 m 3 /s (5,400m 3 /hr) Page 312-317 Eco Mix Flow Fans (eMF)- Up to 5.63m 3 /s (20,268m 3 /hr) Page 318-323 Powerflow In-Line Duct Fans (ACP) -Up to 0.34m 3 /s (1,220m 3 /hr) Page 324-327 EuroSeries ® (SDX) In- Line Centrifugal Fans- Up to 0.35m 3 /s (1260m 3 /hr) Page 328-331 Slimpak® In -Line Centrifugal Fans (SLP)- Up to 0.38m 3 /s (1,368m 3 /hr) Page 332-335 Mixed Flow Fans (MFQ)-Up to 3.67m 3 /s (13,212m 3 /hr) Page 336- 341 TWIN FAN RANGE 342-355 SENTINEL D-BOX 356-383 New Acoustic In-Line Direct Driven Twin Fans (ATQ)- Up to 1.35m 3 /s (4,860m 3 /hr) Page 344-349 Power Twin Fans (TDF )- Up to 3.52m 3 /s (12,672m 3 /hr) Page 350-353 Trakmaster Twin Fan Controllers Page 354-355 Sentinel D-Box Single Fan- Up to 1.49m 3 /s (5,364m 3 /hr) Page 362-371 Sentinel D-Box Twin Fan- Up to 1.20m 3 /s (4,320m 3 /hr) Page 372-381 Sentinel D-Bo x Sensors & Controls Page 382-383 SENTINEL TOTUS 2 D-ERV 384-401 ROOF FAN RANGE 402-425 Sentinel Totus 2 D-ERV Fans-Up to 0.59m 3 /s (2,124m 3 /hr) Page 396-401 NEW High Temperature Roof Fans (RDM)-Up to 8.83m 3 /s (31,788m 3 /hr) Page 404-407 Sabre® Sickle fan assisted roof cowl (VSR)- Up to 5.00m 3 /s (18,000m 3 /hr ) Page 408-415 Mixed Flow Roof Fans (RMH)- Up to 3.63m 3 /s (13,068m 3 /hr) Page 416-421 Lo-Carbon MX Roof Fans (MX)- Up to 1.86m 3 /s (6,696 m 3 /hr) Page 422-425 AIR HANDLING 426-435 ACCESSORIES & CONTROLLERS NON-RESIDENTIAL 436-463 Slimline Range (SL)- Up to 0.92m 3 /s (3,312m 3 /hr) Page 428-431 D1 to D6 Mini Direct Range-Up to 2.25m 3 /s (8,100m 3 /hr) Page 432-435

Lo-Carbon Residential Fans Continuing our commitment to energy efficiency in this section you will find Lo-Carbon solutions for intermittent and continuous fan applications. In axial or centrifugal, wall, ceiling or window applications in bathrooms or kitchens we have a Lo-Carbon fan offering up to 90% energy saving over the equivalent traditional fan. We are proud to be market leaders and continually strive to bring you the best products available. Our newest addition to the range is no different-the NEW Lo-Carbon Revive features a raft of innovations developed specifically for the needs of the Social Housing Market. The unique Multi-Vortex TM airflow technology ensures excellent pressure development yet efficient and quiet operation. Revive's Sense Smart TM intelligent technology makes the fan easy to install and provides a range of data via its easy to use interface.See page 24 for more details.

NEW Lo-Carbon Svara Axial Bathroom/Toilet Fan 30 4 20 0.13 14-15 Lo-Carbon iQ Intelligent Axial Bathroom Fan 37-29-16-17 Lo-Carbon VA100 ® /SELV Axial Bathroom/Toilet Fan 21 7 36 0.33 18- 19 Lo-Carbon Silhouette ® 100/SELV Bathroom/Toilet Fan 30 8.7 38 0.30 20-21 Lo-Carbon Centra ® /SELV dMEV Unit 15 2.4 25.2 0.18 22-23 NEW Lo-Carbon Revive /SELVBathroom/Kitchen Filterless Fan 24-25 Lo-Carbon Solo Plus/SELV Centrifugal Bathroom/Toilet Fan 21 8.4 35.5 0.29 26-27 Lo-Carbon Minivent Ducted Bath/Shower Fan Kit 31 6.5 23 0.21 28 Lo-Carbon LED Vent-A-light Ducted Bath/Shower Fan Kit 31 6.5 23 0.21 29 Lo-Carbon Quadra ® /SELV Centrifugal Fan 63 38 50 0.60 30-31 Lo-Carbon Silhouette ® 125 Bathroom/Toilet Fan 44 8 37 0.18 32 Lo-Carbon VA150 Axial Kitchen & Utility Room Fan 64 36 11.5 0.18 33 Lo-Carbon Silhouette ® 150 Axial Kitchen Fan 34-35

14 The UKs first App controlled unitary fan The launch of Svara marks the next generation of unitary fans. For electricians, installation is made simple through Svara's Bluetooth-enabled App allowing you to choose whether to opt for intermittent or continuous ventilation; whether you would like the humidistat to trigger operation or not; and whether the overrun timer is required. No more fiddly switches and jumpers! For consumers Svara offers improved comfort in their homes since it has been developed to allow households to take control of their indoor air quality via the App. Aesthetics and silence The name Svara takes its influence from the fan's Swedish heritage – a country well known for iconic and well thought out designs. Consumers will be attracted to Svara's good looks with its sleek modern design, plus with noise a key issue for consumers, households will also be impressed by Svara's quiet running, operating at just 17 dBA on low trickle. It is also easy to clean as the cen tral module disconnects the motor from the rest of the fan allowing it to be simply wiped with a soft cloth, and at only 4W the energy efficient Svara also boasts low power consumption. One model fits all Vent-Axia Svara is programmed to cope with the vast majority of installations. The fan is set as default to work continuously at a trickle flow of 10l/s. When the fan senses a somebody in the room it increases the flow to 19l/s. If the humidity rises rapidly, for example when the shower is on, the fan goes up to maximum flow at 30l/s. When the fan senses the humidity level has returned to normal it reverts to the trickle flow of 10l/s. If other settings or functions are desired, they can be selected through the Vent-Axia Connect App which can be downloaded from the App Store and Google Play. Functions Light sensorWhen the light sensor is enabled Svara senses when someone is in the room and then activates. Its sophisticated light sensor is triggered by light movement and shadows. It is possible to set a delay-on so the fan is not triggered by the light during quick night time bathroom visits. The light sensor can also distinguish between headlight flashes from cars and room occupancy, so it is not triggered by passing cars, avoiding nuisance running. The sensitivity of the light sensor can be adjusted via the App. Overrun TimerThe light sensor provides an overrun timer but only requires a live and neutral. In houses where there is only a basic fan installed, the home owner can upgrade to a timer fan without having to rewire. HumidistatSvara features a humidistat which reacts to sharp changes in humidity, for instance when someone is taking a shower. When set to continuous running, once the humidity sensor is activated the fan runs at 30l/s until humidity returns to normal levels then the fan powers down to 10l/s. Ambient humidity changes will not trigger the humidistat. It is possible to change the sensitivity of the humidity sensor via the App. Silent schedulin g and Automatic cyclesThe silent hours scheduling function allows you to deactivate the boost function on the Svara via the App, for example, this would prevent nuisance noise over night. Additionally during a vacation you can set Svara to an airing mode which operates a purge function every 12 hours for either 30, 60 or 90 minutes depending on selection. However, Svara's sophisticated controls, will not purge if the light sensor detects that there is someone in the house. NEW Lo-Carbon Svara • The UK's first App controlled unitary fan ! • Set up and control through the App via Bluetooth • Continuous or intermittent • 1 model for all applications • Silent hours scheduling and purge mode functions • Intelligent light sensor with overrun timer-allows replacement of a basic model fan • 3 Speed, IP44 Rated , DC motor with 5 year guarantee • Suitable for ceiling, panel or wall mounting • Only 17 dBA

15 Models Svara kitchen and bathroom fan100 mm Axial fan. Factory set at continuous running with Humidistat and Light Sensor/overrun timer On. Model Stock Ref £Trade Lo-Carbon Svara 409802 205.09 Accessories Model Stock Ref £Trade Wall Kit 254102 21.55 Model Stock Ref £Trade Back draught shutter 406605 19.46 Cover plate For duct dimensions between Ø140-160mmModel Stock Ref £Trade Cover plate 409820 15.67 Dimensions (mm) ABCDAB CØ DØ 60 21 99 177 Performance Guide Extract Performance-FID (l/s) Sound dB(A ) SFP (W/l/s) Low Trickle High Trickle Boost Max Watts @ 3m @ 0Pa 10 16 30 4 17-20 0.13

16 Lo-Carbon iQ • Minimal retro design to match bathroom décor • Extremely quiet- only 21 dB(A) • Truly surface mountable with removable spigots • Intelligent controls and control panel for easy and flexible set up and commissioning • Low power consumption – only 5 W • Easy cleaning and maintenance • 5 year Lo-carbon motor guarantee • Intelligent humidistat control as standard • Innovative airing function to ensure good air quality • IP44 rated Market Leading Design With the launch of the Lo-Carbon iQ fan, we not only spent time perfecting the operation and user's experience of the fan but also worked hard on the design. The result is a stylish fan with a surface depth that appeals to the eye and that matches modern fittings found in today's bathrooms. The visible blades give a retro -feel and helps to give the fan a very quiet noise level. Silent Operation The open impellor and the unique method of operating the motor enables a greater array of operating options including sil ent continuous ventilation along with adaptable speed control and flexible timer functions. Humidity Control The iQ features an intelligent, fully automatic humidity sensor for moisture control. This means the fan learns to run only when it can make a difference to the indoor air quality. The fan continually monitors and records the moisture content to allow it to map the humidity profile throughout the year. This process enables the fan to ensure that it runs only when the fan can lower the moisture content in the air. This reduces nuisance running. The fan also has two modes for moisture control, silent or boost mode which can be selected via the touch pad control. Control Panel Our aim has been for the end user to be able to control and understand the basic fan functions, without the need of reading the manual. When the fan is connected to the power supply, it also performs a self-test where all the status lamps on the control panel are tested, as well as the function of the motor. Ideal for those installing to ensure that everything works. The simple controls, along with the LED feedback make the commissioning and any readjustment, quick and easy to complete. LED Feedback With many fans it is difficult to understand the exact mode that they are running in . We have now simplified this to provide a visual indicator to see what the fan is doing and which mode is currently active. The fan uses three different colours on the visible status lamp to communicate exactly what it is doing. A blue light signifies that the fan is working to evacuate moisture via the humidity sensor. A yellow light signifies that the timer is running. And a purple light signifies that the fully automatic airing function is active. You Choose How The Fan Works The intelligent overrun timer can be operated in several different ways, either via the light switch, integral pull-cord or a separate switch either as a standard On/Off or as a momentary switch stopping automatically after the overrun on time. You use the control panel to easily set the required post-running time at 15 or 30 minutes, depending on your choice. Full Surface Mounted Installation With the impellor and motor assembly designed to be low profile and accessible for maintenance, spigots on the fan are completely removable. This design enables the fan to be mounted onto a wall without any spigot so that it can be truly surface mounted. This is an ideal function if you have a duct with a smaller dimension than 100 mm or a duct that bends directly off of the back of the fan not providing any depth in the wall for the spigot. Cleaning and Maintenance For a fan to ventilate effectively, it is vital that it is kept clean and that the ductwork and grilles are free from dust that can reduce the air flowing through them. This is the first fan to be introduced with the ability to simply remove the impellor and open the centre of the fan to gain free access to the duct. Using the'swing-out' function you can easily cle an and clear the fan eg a clogged grille on the outside of the façade. Click the button to remove the impellor, then press the snap in catch and swing out the motor-that's it!     

17 Automatic Airing Function The airing function means when the fan has been inactive for 26 hours, it runs an airing programme for 60 minutes to exchange the air in the bathroom. No more worries about stuffy, musty odours in the bathroom when returning from holiday. Lo-Carbon 5 Year Guarantee As there is an integrated power adapter in the fan we have been able to use a low voltage motor that has a life span of approximately 60,000 hours. This is about 3-5 times longer than a standard fan. The motor features extremely quiet bearings. By using a low voltage motor we can significantly limit power consumption. The fan only consumes 5 Watts, about a third of a conventional AC bathroom fan. Models Lo-Carbon iQ Multi control fan with option to run on intermittent or continuous setting. Adjustable timer and humidity options with integral pullcord included.Model Stock Ref £Trade Lo-Carbon iQ 405155 205.09 Accessories Backdraught ShuttersDesigned to reduce any incoming draughts when the fan i s off.Model Stock Ref £Trade Backdraught Shutters 406605 19.46 Wall Mounting Back Plate Designed to cover up marks where a previous fan has a different foot print. 242mm x 190mm. Model Stock Ref £Trade Wall Mounting Back Plate 406762 20.29 Dimensions (mm) DØ ABC ABC DØ 152 202 31 99/125 Product is supplied with a removable spigot 30mm deep in 99mmØ and 125mm Ø Performance Extract Performance-FID Sound dB(A) Duct Ø Trickle/Boost m 3 /hl/s @ 3m 100mm Max 108 30 28 100mm Silent 72 20 21 100mm Trickle 43.2 12 12 125mm Max 133.2 37 29 125mm Silent 86.4 24 21 125mm Trickle 54 15 13

18 Long Life Ventilation VA100 The Vent-Axia Lo-Carbon VA100 range features Lo-Carbon long life DC motors that are more efficient than conventional motors delivering up to 87% energy savings. Shutters The Vent-Axia Lo-Carbon VA100 range is fitted with a motorised shutter mechanism that uses no extra power in operation or off. Installation Fitted with integral protection against low energy lighting circuits, the Lo-Carbon VA100 is a 100mm axial fan suitable for use in the bathroom or toilet. VA100 is quick and simple to fit with easy-wire in one line terminals. Suitable for installation in windows, walls or panels/ceilings using kits available. The 100mm telescopic wall kit fits walls 225 to 360mm thick. The range meets the requirements of the current Building Regulations for the ventilation of toilets 6l/s and bathrooms 15l/s with a 15 minute overrun timer for internal rooms on the LT, XT and HTP models. Safety Extra Low Voltage (SELV) Fan Safety Extra Low Voltage (SELV) is designed f or areas where a fan has to be fitted within zone 1 in a room containing a fixed bath or shower according to IEE wiring regulations. The VA100 SELV can be safely installed within the spray area. The fan is rated IPX7, control is by the supplied mains safety isolating transformer with 12V DC SELV output, which is sited away from any source of spray and out of reach of a person using a fixed bath or shower. Models Lo-Carbon VA100 LP/SELV LP (Pullcord) Ultra long life DC motor Pullcord On/Off override switch with indication light. 2 speed options.Model Stock Ref £Trade LP 443159 61.69 SELV LP 441614 131.21 Lo-Carbon VA100 XP/SELV XP(Shutter/Pullcord) Ultra long life DC motor. Pullcord and On/ Off override switch with indication light. 2 speed options.Model Stock Ref £Trade XP 443160 84.98 SELV XP 459049 144.70 Lo-Carbon VA100 LT/SELV LT (Timer) Electronic adjustable overrun timer (5-30 minutes). Indication light. 2 speed options.Model Stock Ref £Trade LT 443161 76.22 SELV LT 4416 15 140.36 Lo-Carbon VA100 XT/SELV XT (Shutter/Timer) Integral electronic adjustable overrun timer (5-30 minutes). Indication light. 2 speed options.Model Stock Ref £Trade XT 443162 112.41 SELV XT 459050 171.93 Lo-Carbon VA100 LHTP/SELV LHTP (Integral Humidity Sensor/Pullcord/Timer) Complete with integral humidity control with pullcord override. Indication light which operates on the manual override only. 2 speed options.Model Stock Ref £Trade LHTP 443163 195.76 SELV LHTP 441616 225.81 Lo- Carbon VA100 XHTP/SELV XHTP (Shutter/Integral Humidity Sensor/Pullcord/Timer) Complete with integral humidity control with pullcord override. Indication light which operates on the manual override only. IPX4 rated. 2 speed options.Model Stock Ref £Trade XHTP 443164 208.69 SELV XHTP 436064 240.15 Lo-Carbon VA100/SELV • Meets current Building Regulations Approved Document F & L • Suitable for wall, ceiling, panel and window mounting • Fitted with a motorised shutter • Protected against low energy lighting circuits • IPX4 rated-IPX7 rated (SELV) • Efficient long life DC motor with 5 year guarantee • Uses up to 87% less energy • Low sound levels • 1 of 2 speeds selectable at installation • Low specific fan power • Day logger as standard on all models

19 Accessories Wall Kit Fixing hole diameter 117mmØ Model Stock Ref £Trade Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.55 Window Kit Fixing hole diameter 105mmØModel Stock Ref £Trade Window Kit 254101 21.55 Anti-tamper Window Kit 443234 23.32 Dimensions (mm) AAABC DØ EFGHH Panel Wall Window ABC DØ EFGH Bathroom/Toilet 146 47 53 98 31 31 74 200 SELV Transformer (W x H x D) 87 x 87 x 33 Weight 1kg Performance Extract Performance-FID Sound dB(A) SFP (W/l/ s) Area Models m 3 /hl/s Watts @ 3m @ 0Pa Toilet Lo-Carbon VA100/SELV LP/XP/LHTP/XHTP/LT/XT 60 17 3.4 32 0.20 Bathrooms Lo-Carbon VA100/SELV LP/XP/LHTP /XHTP/LT/XT 74 21 7.0 36 0.33

20 Lo-Carbon Silhouette 100/SELV • Models Basic/Timer/Humidity & Timer • Low power consumption-Lower running costs • Fully opening and closing non-transparent shutters-Improved insulation and privacy • Meets current Building Regulations Approved Document F & L • 1 of 2 speeds selectable at installation • Blue power indication light (except B model)-Modern aesthetics • Ball bearing motors for vertical or horizontal application • Unique humidity sensor track-Improved response • 5 Year Motor Guarantee • IPX4 rated-IPX7 rated (SELV ) • Suitable for wall, ceiling, panel and window mounting Slimline Bathroom Ventilation With a slim profile of only 17mm, Lo-Carbon Silhouette blends in with the wall surface to provide an unobtrusive installation. Lo-Carbon Silhouette has an FID performance of up to 30l/s. It can be ceiling/panel mounted and connected to an appropriate duct run to the outside. Safety Extra Low Voltage (SELV) Fan Safety Extra Low Voltage (SELV) is designed f or areas where a fan has to be fitted within zone 1 in a room containing a fixed bath or shower according to IEE wiring regulations. The Silhouette SELV can be safely installed within the spray area. The fan is rated IPX7, control is by the supplied mains safety isolating transformer with 12V DC SELV output, which is sited away from any source of spray and out of reach of a person using a fixed bath or shower. SELV transformer to BS EN 60742. Models Lo-Carbon Silhouette 100B/SELV 100SVB100mm bathroom /toilet fan with back draught shutter.Model Stock Ref £Trade 100B 441624 61.04 SELV 100SVB 441511 118.99 Lo-Carbon Silhouette 100T/ SELV 100SVT (Timer)100mm bathroom/toilet fan with integral adjustable electronic overrun timer (5-30 minutes), indicator light which operates on manual override only, and back draught shutter.Model Stock Ref £Trade 100T 441625 76.28 SELV 100SVT 441512 144.95 Lo-Carbon Silhouette 100HT (Humidistat/Timer) 100mm bathroom/toilet fan with adjustable auto humidity sensor from 60-90% RH and overrun timer, indicator light which operates on manual override only, and back draught shutter. Datalogger as standard on all Lo-Carbon humidity controlled Silhouette fans. Model Stock Ref £Trade 100HT 441626 126.64 Lo-Carbon Silhouette 100H SELV (Humidistat)100mm bathroom/toilet fan with ambient response humidity sensor from 60-90% RH, indicator light which operates on manual override only, and back draught shutter. Safety Extra Low Voltage version.Model Stock Ref £Trade SELV 100SVH 441513 195.27 Accessories Wall Kit Fixing hole diameter 117mmØ Model Stock Ref £Trade Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.55 Window Kit Fixing hole diameter 117mmØModel Stock Ref £Trade Window Kit 442947 23.32 17mm actual profile

21 Dimensions (mm) Panel Wall Kit AA ØB CDEFE A BØ CDEF 160 99 115 132 200 32 SELV Transformer (WXHXD) 87 X 87 X 33 Weight 0.6kg Performance Guide 0 5 10 15 20 25 0 5 10 15 20 30 Air Volume l /s Pressure Pa 30 35 25 35 1 2 Extract Performance-FID Sound dB(A) SFP (W/l/s) Area Model Curve Ref m 3 /hl/s Watts @ 3m @ 0Pa Toilet Lo-Carbon Silhouette 100 B/ T/HT/SVB/SVT/SVH 1 60 17 3.4 34 0.20 Bathrooms 2 108 30 8.7 38 0.30 For window mounting: shutter cannot be used and must be removed

22 Lo-Carbon Centra/SELV • Building Regulations Approved Documents F and L compliant, System 3 Continuous mechanical extract • Recognised in SAP PCDB-Low SFP • Discreet, tasteful styling • IPX4 rated-IPX7 rated (SELV) • dMEV Pressure detection device • 5 Year Motor Guarantee • Suitable for wall, ceiling, panel and window mounting • SELV models supplied with remote transformer and suitable for'Zone 1'What is de-centralised MEV (dMEV)? Building Regulations Approved Document F gives examples of four main methods of ventilation. System 3, Continuous mechanical extract ventilation, can be achieved using a single centralised extract unit such as the Sentinel Multivent ducted to'wet' rooms (kitchen, bathroom, en-suite and WC) or by decentralised individual fans, such as the Lo-Carbon Centra in the'wet' rooms. The fans run continuously at near silent levels providing a simple and effective form of ventilation. SELV (Safety Extra Low Voltage) is designed for areas where a fan can be installed within Zone 1 in a room where there is a fixed bath or shower. Ingress Protected (IP) to IPX7 Lo-Carbon Centra SELV can be fitted safely within the spray area. The separate transformer can be mounted away from the spray zone and out of reach from the bath or shower. The Lo-Carbon Centra meets the latest requirements of the Building Regulations Approved Document F for wholehouse system ventilation and all models come with a 5 year motor guarantee. Selection of the two trickle flow rates (6l /s or 9l/s) is via a simple'jumper' on the control board. Different methods are available for operating the 15 l/s boost speed from a simple switched live to integral humidistat. See individual models for further details. The attractive and discreet styling of the Vent-Axia Lo-Carbon Centra will complement the décor of any new home while virtually silent operation ensures optimum ventilation is achieved without intrusive noise. Specific Fan Power dMEV version recognised in SAP PCDB. Lo-Carbon Centra has a specific fan power of only 0.18 W/l/s in through-the-wall kitchen applications. Models Lo-Carbon Centra dMEV Auto speed selection at installation and suitable for bathrooms or kitchens. The integral air pressure sensor checks the airflow when first installed and also helps the fan to compensate for external wind pressure. Stock Ref £Trade 441782 123.19 Lo-Carbon Centra T/SELV T (Timer)Ideal for bathroom and toilet applications, this unit runs continuously on trickle setting and may be boosted by the switched live input which activates the timer (fixed 15 min on T models, adjustable 5-30 minutes on SELV models).Model Stock Ref £Trade T 442954 139.62 SELV T 443175 171.28 Lo-Carbon Centra TP/SELV TP ( Timer/Pullcord)For bathroom/toilet applications, the continuous running TP model is boosted by the pullcord which activates the timer (fixed 15 min on TP models, adjustable 5-30 minutes on SELV models).Model Stock Ref £Trade TP 447127 156.68 SELV TP 447128 187. 67 Lo-Carbon Centra HT/SELV HT (Humidistat/Timer)For bathroom/toilet applications, the continuous running HT model is automatically boosted by the built-in humidistat or by a switched live input which activates the timer (fixed 15 min on HP models, adjustable 5-30 minutes on SELV models). Model Stock Ref £Trade HT 442955 182.51 SELV HT 443176 214.44 Lo-Carbon Centra HTP/SELV HTP (Humidistat/Timer/Pullcord)For bathroom/toilet applications, the continuous running HTP model is automatically boosted by the built-in humidistat or by the pullcord which activates the timer (fixed 15 min on HTP models, adjustable 5-30 minutes on SELV models). Model Stock Ref £Trade HTP 443045 182.51 SELV HTP 443177 214.44 WINNER 2011 Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range

23 Accessories Model Stock Ref £Trade 150mm Conversion Kit 443334 28.65 Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.55 Window Kit 442947 23.32 Ceiling Kit 443800 15.84 Dimensions (mm) DØ AABC Model ABC DØ Lo-Carbon Centra dMEV/All SELV 160 35 115 99 Lo-Carbon Centra T/TP/HT/HTP 160 35 80 99 Transformer 87 x 87 x 33mm (W x H x D) (SELV models only) Performance Guide Extract Performance (l/s) Power Consumption (Watts) Sound dB (A)@ 3m Trickle Trickle Trickle Trickle Trickle Trickle Trickle Model Low High Boost Low High Boost Low High Boost Lo-Carbon Centra dMEV/All SELV 6 9 15 1.4 1.6 2.4 10.8 15.5 25.2 Lo-Carbon Centra T/TP/HT/HTP 6 9 15 3.2 3.5 4.2 10.8 15.5 25.2 SAP PCDB Performance (dMEV model) Systems With Rigid Ductwork Installation Only Unit Configuration Location Fan Speed ​​Setting Flow Rate (l/s) SFP (W/l/s) In Room (Ducted) Kitchen High 13.2 0.32 In Room (Ducted) Wet Room 9 l/s 8.4 0.28 Through Wall Kitchen High 13.5 0.18 Through Wall Wet Room 9 l/s 8.6 0.20 Systems With F lexible Or Mixed Ductwork Installation Only Unit Configuration Location Fan Speed ​​Setting Flow Rate (l/s) SFP (W/l/s) In Room (Ducted) Kitchen High 13.2 0.37 In Room (Ducted) Wet Room 9 l/s 8.6 0.31 Through Wall Kitchen High 13.5 0.18 Through Wall Wet Room 9 l/s 8.6 0.20

24 NEW Lo-Carbon Revive/SELV • Designed specifically with Social Housing in mind • Continuous running bathroom and kitchen fan • Extracts up to 60l/s • Easy to read LED display for commissioning and data gathering • Intelligent Smart Sense TM technology tells you days run, boost hours run, energy used • Innovative Multi-Vortex technology ensure high performance but low sound and energy levels • 5 or 7 year warranty options • Small footprint with optional decoration frame Designed for Social Housing The intelligent Lo-Carbon Revive is a new filter-less unitary fan designed to meet the specific needs of social housing. Boasting powerful, quiet, efficient ventilation, Revive provides good indoor air quality and comfort for residents while being quick and easy to install, low maintenance and reliable. Smart Sense TM technology Featuring Smart Sense™ intelligent technology Revive is quick and easy to install due to its simple alpha numeric LED display which is clear, easy to re ad and has a three-button menu for commissioning and data gathering. Smart Sense™ technology even tells the LED display which orientation to use depending on whether it is wall or ceiling mounted. All of which saves time on site and reduces installation complications. The display also shows real-time data so landlords can reassure residents of the low-running costs. This includes data such as days run, hours on trickle or boost, and even more specifically, hours run on boost triggered by the humidity sensor. Revive can also tell you how much energy the fan has used. Multi-Vortex TM technology Revive is low maintenance since its market-leading Multi-Vortex™ technology does not require a filter, while the highly sculpted interior actively repels dust, avoiding clogging, thus helping to avoid call backs. In addition the Multi-Vortex TM technology has a high-pressure hybrid impellor that is powerful and efficient, yet quiet – everything you need for the Social Housing resident. Multiple c onfiguration options Revive can extract up to 60l/s from a kitchen, but upon installation you have the choice to change the setting to allow for installation in a bathroom. The installer can also select a ducted mode or a through the wall mode. All selected via the intuitive LED display. Models Lo-Carbon Revive 7/SELV 7HTP continuous running fan with kitchen or bathroom setting, with a combination of trickle and boost speeds selectable from 9, 15, 30 and 60l/s. Day logger and power run meter as standard. 7 year warranty. Adjustable dynamic ambient response humidity sensor. Timer adjustable between 1 and 30 minutes. In built boost activated by pullcord, humidity sensor, switched live or remote button. Tile front for discreet installation. Model Stock Ref £Trade Lo -Carbon Revive 7 473848 328.39 Lo-Carbon Revive SELV 7 473849 377.29 Lo-Carbon Revive 5/SELV 5HTP continuous running fan with kitchen or bathroom setting, with a combination of trickle and boost speeds selectable from 9, 15, 30 and 60l/s. Day logger and power run meter as standard. 5 year warranty. Adjustable dynamic ambient response humidity sensor. Timer adjustable between 1 and 30 minutes. In built boost activated by pullcord, humidity sensor, switched live or remote button. Open front grille.Model Stock Ref £Trade Lo-Carbon Revive 5 473850 278.78 Lo-Carbon Revive SELV 5 473851 357.05 Lo-Carbon Revive/SELV HTP continuous running fan with kitchen or bathroom setting, with a combination of trickle and boost speeds selectable from 9 , 15, 30 and 60l/s. 5 year warranty. Adjustable dynamic ambient response humidity sensor. Timer adjustable between 1 and 30 minutes. In built boost activated 

25 by pullcord, humidity sensor, switched live or remote button. Open front grille.Model Stock Ref £Trade Lo-Carbon Revive 473852 237.56 Lo-Carbon Revive SELV 473853 310.45 Accessories Model Stock Ref £Trade Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.55 Conversion kit 408680 28.17 Ceiling kit 407928 16.41 Window kit 407927 23.67 Decoration Frame 474041 11.00 Dimensions (mm) DBA CØ DAB CØ D 30 132/102 99 193 Closed/Open Grille Decoration Frame Dimensions (mm) ACABABC 259 191 10 Performance Guide Pr es su er P a Volume Flow l/s Low Kitchen Boost High Kitchen Boost Low Trickle Bathroom Boost 0 20 40 60 80 100 120 140 160 0 10 20 30 40 50 60 1 1 2 2 3 3 4 4 Extract Performance (l/s) Power Consumption (Watts) Model Trickle Low Bathroom Boost Low Kitchen Boost High Kitchen Boost Trickle Low Bathroom Boost Low Kitchen Boost High Kitchen Boost Revive 9 15 30 60 1.4 2 6 26  

26 Lo-Carbon Solo Plus/SELV • Up to 70% energy saving • Filterless as standard-innovative impeller design means no need for a filter • 5 Year Lo-Carbon motor guarantee • Meets current Building Regulations Approved Documents F & L • IPX4 rated -IPX7 rated (SELV) • Flush or surface mountable with adjustable rear or side exit spigot • SELV models suitable for installation over or within reach of a shower or bath • Extremely low sound levels • Suitable for wall, ceiling and panel mounting • SELV Models -Supplied with a remote transformer Long Life Ventilation The Lo-Carbon Solo Plus range from Vent-Axia has been specially designed for through the wall and ducted applications, suitable for internal bathrooms, toilets and other small rooms. Finished in white, the Lo- Carbon Solo Plus can be flush or surface mounted, with a 2 position 100mm circular spigot for rear entry or connecting to a vertical ducting system. The powerful centrifugal impeller allows installations using 100mm ducting in straight runs, whilst still achieving 15l/s as required by Building Regulations Approved Document F. Continuous running products, such as the Lo-Carbon Solo Plus, installed in all wet areas of a dwelling are classed as a wholehouse ventilation system and therefore only need to move the amount of air as outlined in table 5.1a and 5.1b of Building Regulations Approved Document F. The Lo-Carbon Solo Plus has an adjustable boost speed which is set at installation variable between a wall or duct setting for boost/ override operation to meet Building Regulations thus ensuring minimum energy usage and low sound levels. All models have an optional speed for constant trickle ventilation (12l/s), selectable at installation. Depending on the model, the fan will switch from trickle (if selected ) to boost via the pullcord/light switch/humidity sensor/PIR. All models can be wall, panel or ceiling mounted and can be connected to either circular, rectangular or Vent-Axia's flat ducting. Enc losure of the electrical components is manufactured from flame retardant grade material. Safety Extra Low Voltage Fan (SELV) Designed for areas where a fan has to be fitted over or within Zone 1 in a room containing a fixed bath or shower according to IEE wiring regulations (BS 7671), the Lo-Carbon Solo Plus SELV fan can be safely installed within the spray area. The fan is rated IPX7. Control is by the supplied mains safety isolating transformer unit with 12V DC SELV output, which is sited away from any source of spray and out of reach of a person using a fixed bath or shower. Controller Supply voltage 220-240V/1/50Hz. Output to fan SELV 12V DC. Models Lo-Carbon Solo Plus P/SELV P (Pullcord) Flush or surface mountable. Control by Pullcord. 2 Speed. Constant trickle option. Adjustable boost. In-built Lo-Carbon controller. Model Stock Ref £Trade P 427481 151.04 SELV P 427485 160.21 Lo-Carbon Solo Plus T/SELV T (Timer) Flush or surface mountable. Control by room light or switch. 2 Sp eed. Constant trickle option. Adjustable boost. Adjustable timer overrun. Delay on timer. In-built Lo-Carbon controller.Model Stock Ref £Trade T 427482 173.05 SELV T 427486 183.08 Lo-Carbon Solo Plus HT/SELV HT (Humidistat/Timer ) Flush or surface mountable. Humidity controlled fan with override pullcord. Constant trickle option. Adjustable boost. Adjustable timer overrun. Delay on timer. Adjustable humidity sensor. In-built Lo-Carbon controller. Datalogger as standard on all Lo-Carbon humidity controlled Solo Plus fans. Model Stock Ref £Trade HT 427483 244.09 SELV HT 427487 251.75 Lo-Carbon Solo Plus TM/SELV TM (Timer/PIR) Flush or surface mountable. Control by integral PIR detector. 2 Speed. Constant trickle option. Adjustable boost . In-built Lo-Carbon controller.Model Stock Ref £Trade TM 427484 343.28 SELV TM 427488 350.90

27 Dimensions (mm) BDCAEFHIJG ABCD EØ FGHIJ 263 224 106 55 98 62 65 98 21 34 Weight 2.2kg, SELV Weight 2.7kg. Dimensions: (W x H x D) 87x87x33mm. Performance Guide (Duct Mode) 1 2 3 0 20 40 60 80 100 120 0 5 10 15 20 25 Pr e ssu er P a Volume Flow l/s Boost Low Trickle High Trickle 1 2 3 Extract Performance l/s (m 3 /h) Power consumption-Watts dB(A) @ 3m SFP (W/l/s) Model Boost High trickle Low Trickle Boost High trickle Low Trickle Boost High trickle Low Trickle @ 0Pa Lo-Carbon Solo Plus/SELV P/T/HT/TM Wall mode 18 (64.8) 12 (43.2 ) 8 (28.8) 6 2.9 2.3 33.5 27 23.5 0.28 Duct mode 21 (75.6) 17 (61.2) 11 (39.6) 8.4 5.3 3.2 35.5 33 26 0.29 Tested at 240VAC @ 50Hz Accessories Lo-Carbon Solo Plus Bezel Used when flush mounting- reduces the need to make good.Model Stock Ref £Trade Bezel 404 106 11.89 Model Stock Ref £Trade Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.55 Filter pack (1 per pack)The design of the Lo-Carbon Solo Plus means that it does not need a filter. Howe ver, if you are going to install the product in a heavily greasy environment, you may want to protect the product by fitting a filter.Model Stock Ref £Trade Filter pack 449265 5.88

28 Powerful Lo-Carbon In-Line Fan Kit The Vent-Axia Lo-Carbon Minivent ducted bath/shower kit includes all the components necessary to install a ducted 100mm system. This simplifies fitting of an efficient ventilation system to small rooms including bathrooms, shower rooms and toilets. It is especially suitable for en-suite bathrooms. Lo-Carbon Minivent Shower Kit installed When installed, the fan kit has ample performance to meet the Building Regulations requirements for toilets and bathrooms. The timer version should be used for internal rooms . The kit consists of a Lo-Carbon Minivent In-Line fan, a white ceiling grille and spigot, 3 metres of flexible duct and an external louvre for soffit or wall mounting. The duct should be cut to the required length and the bend radius kept to a maximum to provide optimum fan performance. Enclosed terminal compartment, Class 2 appliance. Supply voltage 220-240/1/50Hz. Models Lo-Carbon Minivent Shower Fan (Basic)Comprises-high output tube fan, 3 metres of flexible duct, ceiling inlet grille and spigot, soffit/wall outlet grille.Model Stock Ref £Trade Basic 441421 62.04 Lo-Carbon Minivent Shower Fan (Timer)Comprises-high output tube fan, 3 metres of flexible duct, ceiling inlet grille and spigot, soffit/wall outlet grille.Model Stock Ref £Trade Timer 441422 74.76 Dimensions (mm) AB Rear View C DØ E Side View ABC DØ E 130 155 90 98 27 Internal/External Grille Dimensions 140x140mmTransformer (W x H x D) 87 x 87 x 33 Performance Guide Extract performance-FID Sound dB(A) SFP (W/l/s) Model m 3 /hl/s Watts @ 3m @ 0Pa Lo-Carbon Minivent B/T 110 31 6.5 23 0.21 Lo- Carbon Minivent • Complete kit supplied • Meets Building Regulations Approved Document F & L requirements for toilets and bathrooms at max 1.5m of ducting and 1x 90° bend • Adjustable timer version available • 5 Year Motor Guarantee • 1 of 2 speeds selectable at installation cting 

29 100mm Lo-Carbon axial in-line shower fan and light kit. Provides simultaneous fan and light operation. Suitable for shower enclosures and wet areas. Available with both a white and chrome bezel on light assembly. The light assembly can be held in place using fixing clips or screws. Typical Specification CE marked in accordance with all the relevant EEC Harmonised Directives. Fan double insulated and the motor is fitted with Thermal Protection. Light assembly class III. Electrical 12 volt DC 3W GU5.3 sealed lamp. Powered by an LED Driver. LED lamp lumens output 180lm – 200lm Input, AC. Output-12 volt DC. 1A. Models Lo-Carbon Vent-A-Light Fan and LED Light Kit (Basic)100mm axial in-line shower fan and light kit . Includes fan, 3m flexible ducting, white grille, LED lamp light transformer and light assembly with white and chrome bezels.Model Stock Ref £Trade Basic 441423 129.68 Lo-Carbon Vent-A-Light Fan and LED Light Kit (Timer)100mm axial in-line shower fan and light kit. Fan has electronic overrun timer adjustable from 5 to 30 minutes. The factory setting is 15 minutes. Includes fan, 3m flexible ducting, white grille, LED lamp light transformer and light assembly with white and chrome bezels. Model Stock Ref £Trade Timer 441424 144.95 Dimensions ( mm) E Side View Rear View DØ ABC GH Ø FABC DØ E FØ G HØ 130 155 90 98 27 140 74 98 Internal/External Grille Dimensions 140x140mmFan Transformer (W x H x D) 87 x 87 x 33 Performance Guide Extract performance-FID Fan Watts Light Watts Sound dB(A) @ 3m SFP (W/l/s) @ 0Pa Model m 3 /hl/s Lo-Carbon Vent-A-Light B/T 110 31 6.5 3 23 0.21 Tested at 240V 50Hz Lo -Carbon LED Vent-A-Light • Suitable for shower enclosure and wet areas • Now with a 3W LED Lamp • Provides simultaneous fan and light operation • Meets current Building Regulations Approved Documents F & L • 1 of 2 speeds selectable at installation • Double insulated fan • Light assembly Class III • 5 Year Motor Guarantee • Supplied with white and chro me bezels

30 Lo-Carbon Quadra/SELV • Meets current Building Regulations Approved Document F & L for intermittent or continuous use • Recognised in SAP PCDB-Low SFP on PCDB 0.38 W/l/s • 100mm circular spigot for easy installation and replacement of any existing fan-flush or surface mount • Filterless technology and maintenance free • Lo-Carbon motors offering 90% energy savings and long life • Motor cassette cartridge for simple replacement • Integral daylogger (option on SELV models) • 5 Year Motor Guarantee • IPX4 rated- IPX7 rated (SELV) • Suitable for wall, ceiling and panel mounting Ventilation for any room The Lo-Carbon Quadra offers a single fan suitable for surface or flush mounting. Low speed selectable between 6, 9 and 12l/s and high between 15, 30 and 60l/s all with through the wall or two ducted selections to ensure installed performance is met. Lo-Carbon Quadra SELV The Lo-Carbon Quadra SELV has been designed to meet building requirements where there is a need to fit i n Zone 1 containing a fixed bath or shower according to IEE wiring regulations. The Lo-Carbon Quadra SELV can be safely installed within the spray area with the 24VDC Safety Isolating Power Supply situated away from the spray zone and out of reach of the person using the facility. Discrete With discrete aesthetics and low noise levels due to an accurately balanced impeller, it is also one of the most unobtrusive centrifugal kitchen fans available. The front cover design also provides no area for dirt to build up so it stays looking better for longer. Models Lo-Carbon Quadra TP/SVTP (Timer/Pullcord)Dual speed: continuous running or intermittent to high speed. High speed via pullcord (On/Off) or switch live (with overrun timer). Model Stock Ref £Trade TP 439251 244.69 SVTP 442865 281.39 SVTP Datalogger 446269 319.76 Lo-Carbon Quadra HTP/SVHTP (Humidistat/Timer/Pullcord) Dual speed: continuous running or intermittent to high speed. High speed via integral pullcord (On/Off), integra l adjustable humidity sensor or switch live (with overrun timer). When humidity sensor is triggered the flow rate increases proportionally with %RH to 50% of the set Boost speed.Model Stock Ref £Trade HTP 439181 287.14 SVHTP 442866 329.37 SVHTP Datalogger 446270 367.76 Lo-Carbon Quadra TM/SVTM (Timer/PIR) Dual speed: continuous running or intermittent to high speed. High speed via integral PIR sensor or switch live (both with overrun timer).Model Stock Ref £Trade TM 439253 338.24 SVTM 442867 388.61 Accessories Model Stock Ref £Trade Flush Mounting Kit 439256 14.33 Filter (optional) 439927 7.16 Decoration Frame 442551 20.29 Wall Kit White 254102 21.55 Wall Kit Brown 254100 21.55 WINNER 2011 Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range .

31 Dimensions (mm) ACFD EØ BHG Rear View Front View Side View A BCD EØ FGH 230 260 112 67 98 27 58 79 Performance Guide 1 2 3 6 l/s 9 l/s 12 l/s 4 5 6 15 l/s 30 l/s 63 l/s 0 50 100 150 200 250 300 0 10 20 30 40 50 60 70 Volume (l/s) Pressure (P a) 4 5 6 Boost Speed ​​Volume (l/s) Pressure (P a) 0 10 5 15 20 0 10 15 5 20 3 2 1 Continuous Trickle Speed ​​Extract Performance Power Sound High Low High Low dB(A) @ 3m SEC Model m 3 /hl/sm 3 /hl/s Watts Watts High Low Class Lo- Carbon Quadra/SELV TP/ HTP/ TM 227 63 22 6 38 3.8 50 20 D FID Performance. Tested in through the wall installation SAP PCDB Performance Systems With Rigid Ductwork Installation Only Unit Configuration Location Fan Speed ​​Setting Flow Rate (l/s) SFP (W/l/s) In Room Kitchen 15 l/s 15.8 0.41 In Room Wet Room 9 l/s 14.6 0.61 Through Wall Kitchen 15 l/s 21.4 0.38 Through Wall Wet Room 9 l/s 19.5 0.50 Systems With Flexible Or Mixed Ductwork Installation Only Unit Configuration Location Fan Speed ​​Setting Flow Rate (l/s) SFP (W/ l/s) In Room Kitchen 15 l/s 13.7 0.41 In Room Wet Room 9 l/s 12.9 0.63 Through Wall Kitchen 15 l/s 21.4 0.38 Through Wall Wet Room 9 l/s 19.5 0.50

32 Lo-Carbon Silhouette 125 • Models Basic/Timer/Humidity & Timer • Low power consumption-Lower running costs • Quiet running • Fully opening and closing non transparent shutters-Improved insulation and privacy • 1 of 2 speeds selectable at installation • IPX4 rated • Ball bearing motors for vertical or horizontal application • Unique humidity sensor track-Improved response • 5 Year Motor Guarantee • Suitable for wall, ceiling and panel mounting Slimline Bathroom Ventilation With a slim profile of only 18mm, Lo-Carbon Silhouette blends in with the wall surface to provide an unobtrusive installation. Lo-Carbon Silhouette has a FID performance up to 160m 3 /h. It can be ceiling/panel mounted and connected to an appropriate duct run to the outside. Models Lo-Carbon Silhouette 125B 125mm bathroom/ toilet fan with indicator light and back draught shutter.Model Stock Ref £Trade 125B 446483 118.99 Lo-Carbon Silhouette 125T (Timer)125mm bathroom/toilet fan with integral adjusta ble electronic overrun timer (5-30 minutes), indicator light which operates on manual override only, and back draught shutter.Model Stock Ref £Trade 125T 446484 134.26 Lo-Carbon Silhouette 125HT (Humidistat/Timer)125mm bathroom/toilet fan with integral adjustable auto humidity sensor from 60-90% RH and overrun timer, indicator light which operates on manual override only, and back draught shutter. Datalogger as standard on all Lo-Carbon humidity controlled Silhouette fans. Model Stock Ref £Trade 125HT 446485 225.23 Accessories Model Stock Ref £Trade Wall Kit 455226 24.43 Dimensions (mm) Panel A BØ CD